INCISIVE Implementation Guide
0.1.1 - draft

INCISIVE Implementation Guide - Local Development build (v0.1.1) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

: Symptoms model of Lung cancer to the FHIR Profile map - XML Representation

Draft as of 2024-03-19

Raw xml | Download



<ConceptMap xmlns="http://hl7.org/fhir">
  <id value="LungSymptomsConceptMap"/>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p>Mapping from <a href="StructureDefinition-LungSymptomsLogicalModel.html">Symptoms Lung</a> to https://simplifier.net/INCISIVE/StructureDefinition/ConditionForBreastColorectalProstate</p><p>DRAFT (not intended for production usage). Published on 2024-03-19 13:26:22+0100 by INCISIVE (INCISIVE: <a href="https://incisive-project.eu/">https://incisive-project.eu/</a>, <a href="mailto:fhir@incisive-project.eu">fhir@incisive-project.eu</a>). </p><div><p>Symptoms model of Lung cancer to the FHIR Profile map</p>
</div><br/><p><b>Group 1</b>Mapping from <a href="StructureDefinition-LungSymptomsLogicalModel.html">Symptoms Lung</a> to <code>https://simplifier.net/INCISIVE/StructureDefinition/ConditionForBreastColorectalProstate</code></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>LungSymptomsLogicalModel.symptomsID (An identifier for the patient symptoms)</td><td><a href="http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#relatedto" title="relatedto">is related to</a></td><td>Condition.id</td></tr><tr><td>LungSymptomsLogicalModel.patientID (INCISIVE patient)</td><td><a href="http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent" title="equivalent">is equivalent to</a></td><td>Condition.subject.reference</td></tr><tr><td>LungSymptomsLogicalModel.otherSymptoms (Clinical finding (finding))</td><td><a href="http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#relatedto" title="relatedto">is related to</a></td><td>Condition.evidence</td></tr></table></div>
  </text>
  <url
       value="https://fhir.incisive-project.eu/ConceptMap/LungSymptomsConceptMap"/>
  <version value="0.1.1"/>
  <name value="LungSymptomsConceptMap"/>
  <title value="Symptoms model of Lung cancer to the FHIR Profile map"/>
  <status value="draft"/>
  <experimental value="true"/>
  <date value="2024-03-19T13:26:22+01:00"/>
  <publisher value="INCISIVE"/>
  <contact>
    <name value="INCISIVE"/>
    <telecom>
      <system value="url"/>
      <value value="https://incisive-project.eu/"/>
    </telecom>
    <telecom>
      <system value="email"/>
      <value value="fhir@incisive-project.eu"/>
    </telecom>
  </contact>
  <description value="Symptoms model of Lung cancer to the FHIR Profile map"/>
  <purpose
           value="It shows how the symptoms model of Lung cancer is mapped into the FHIR Profile/structureDefinition"/>
  <sourceUri
             value="https://fhir.incisive-project.eu/StructureDefinition/LungSymptomsLogicalModel"/>
  <targetUri
             value="https://simplifier.net/INCISIVE/StructureDefinition/ConditionForBreastColorectalProstate"/>
  <group>
    <source
            value="https://fhir.incisive-project.eu/StructureDefinition/LungSymptomsLogicalModel"/>
    <target
            value="https://simplifier.net/INCISIVE/StructureDefinition/ConditionForBreastColorectalProstate"/>
    <element>
      <code value="LungSymptomsLogicalModel.symptomsID"/>
      <display value="An identifier for the patient symptoms"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="relatedto"/>
        </modifierExtension>
        <code value="Condition.id"/>
        <equivalence value="relatedto"/>
      </target>
    </element>
    <element>
      <code value="LungSymptomsLogicalModel.patientID"/>
      <display value="INCISIVE patient"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="equivalent"/>
        </modifierExtension>
        <code value="Condition.subject.reference"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
    <element>
      <code value="LungSymptomsLogicalModel.otherSymptoms"/>
      <display value="Clinical finding (finding)"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="relatedto"/>
        </modifierExtension>
        <code value="Condition.evidence"/>
        <equivalence value="relatedto"/>
      </target>
    </element>
  </group>
</ConceptMap>

INCISIVE has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 952179. However, the content of this website reflects the opinion of its authors and does not in any way represent opinions of the European Union. European Commission is not responsible for any use that may be made of the information the website contains.
https://ec.europa.eu/digital-single-market/en/policies/ehealth